English
한국어
Tiếng Việt
Deutsch
Português
Español
Pусский
Français
العربية
简体中文

Home » Door Hardware Resources » Fire Rated Door & Hardware Info » International Standard of Fire Door

Product Category

Door Hinge

UL Listed Fire Rated Hinge

ANSI / BHMA Door Hinge

CE Grade 13 Door Hinge

Spring Hinge

Security Door Hinge

Flag Hinge

Flush Hinge

Lift-off Door Hinge

Crank Hinge

Piano Hinge

Heavy Duty Door Hinge

Electrified Hinge

Brass Hinge

Hidden Hinge

CE EN1935 3D Hinge

Concealed Hinge

Adjustable Door Hinge

Panic Exit Device

CE Panic Exit Device

UL Fire Exit Hardware

UL305 Panic Hardware

Panic Door Bar

Exit Device Trim

Door Lock

CE EN12209 Mortise Lock

Euro Mortise Lock

UL Mortice Lock

ANSI Cylindrical Lockset

Door Knob Lock

Sliding Door Lock

Narrow Stile Lock

Padlock

Rim Lock

Smart Lock

Smart Door Locks

Hotel Door Lock

Door Closer

UL Listed Fire Door Closer

CE EN1154 Door Closer

Automatic Door Closer

Sliding Door Closer

Hydraulic Door Closer

Spring Door Closer

Commercial Door Closer

Door Coordinator

Lock Cylinder

BS EN1303 Lock Cylinder

Euro Lock Cylinder

Rim Cylinder

Key Cylinder

Cylinder Thumbturn

Door Handle

ANSI Door Handle

BS EN1906 Door Handle

Hollow Lever Handle

Solid Lever Handle

Narrow Frame Lever Handle

Backplate Door Handle

Rosette / Escutcheon

Door Stopper

Door Holder

Floor Door Stop

Wall Door Stop

Rubber Door Stop

Magnetic Door Stop

Half Moon Door Stop

Foot Operated Door Stop

Door Bolt

Flush Bolt

Barrel Bolt

Automatic Flush Bolt

Brass Door Bolt

Stainless Steel Door Bolt

Dust Proof Socket

Door Viewer

Glass Hardware

Glass Door Handle

Glass Door Hinge

Glass Clip

Patch Fitting

Floor Spring

Door Accessories

Ball Catch

Door Guard Chain

Sign Plate

Door Plate

Metal Door Fitting

Thumbturn Indicator

Door Seal

Door Bottom Seal

Intumescent Pads

Door Frame Seal

International Standard of Fire Door

Publish Time: 2021-08-25     Origin: D and D Hardware

Fire rated door refers to the door that can meet the requirements of fire stability, integrity and thermal insulation in a certain period of time, together with the frame. Fire doors are one of the measures for the fire separation of buildings. They are usually used for firewalls, stairwell entrances and exits or pipe shafts where smoke and fire separation is required.

Fire doors not only have the function of ordinary doors, but they also have the function of preventing the spread of fire and smoke. They prevent the spread of fire for a certain period of time and ensure the evacuation of people.

  

There are only 2 international standards all over the world--EN and US. We can study the criteria of door from the following two aspects:

  1. The Fire rated door standards in the United States

  2. The Fire proof door standards in Europe

 

1. Fire rated door standards in the United States

Fire rated doors are tested in accordance with the following standards:

UL 10B, Fire Tests of Door Assemblies (neutral or negative pressure)

UL 10C, Positive Fire Pressure Tests of Door Assemblies

NFPA 252, Standard Methods of Fire Tests of Door Assemblies

 

The basic requirements for fire rated door assemblies include:

Fire ratings (20/45/60/90/180 minutes) are granted by third-party testing agencies and are labeled on the products.

Fire rated door assemblies must meet the requirements of the applicable building or life safety code, such as the National Fire Protection Association (NFPA) 80: Standard for Fire Doors and Other Opening Protectives, NFPA 101: Life Safety Code, the International Building Code (IBC) and the International Fire Code (IFC).

Fire doors are required to be self-closing and positive latching.

The fire rating of the wall dictates the fire rating of the door.

Standards and Testing

 

Fire Door Inspection:

During everyday use, a fire door seems just like any other door.  But when a fire occurs, these doors Prevent Fire from spreading from the area of origin to other Protected areas within the building.


NFPA 80 recommends regular inspection and maintenance plans implemented and managed by the property management department.

 

NFPA 101 also requires that specific doors to be inspected and tested at least once a year, firewalls, barriers and partitions should be maintained in accordance with NFPA 80.

 

NFPA 80 requires the following content to be verified:

(1) No open holes or breaks exist in surfaces of either the door or frame.

(2)Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped.

(3) The door, frame, hinges, hardware, and non-combustible threshold are secured, aligned, and in working order with no visible signs of damage.

(4) No parts are missing or broken.

(5) Door clearances at the door edge to the frame, on the pull side of the door, do not exceed clearances list in 4.8.4 and 6.3.1.

(6) The self-closing device is operational, that is, the active door completely closes when operated from the full open position.

(7)If a coordinator is installed, the inactive leaf closes before active leaf.

(8) Latching Hardware operators and secures the door when it is in the closed position.

(9) Auxiliary hardware items that interfere or prohibit operations are not installed on the door or frame.

(10) No field modifications to the door assembly have been performed that void the label.

(11)Casketing and edge seals, where required, are inspected to verify their presence and integrity

 

2. Fire proof door standards in Europe

Compared with other European countries, the British fire code is very complete and comprehensive. To understand the European door hardware, it is very helpful to refer to the British Fire Code.

Now Britain has the same fire door test standard as Europe EN1634.

 

Fire protection regulations in Britain require hardware matching: in addition to the hardware on the fire door must pass the fire detection EN1634 together with the fire door. Fire door hardware must also meet the form of CE/EN testing requirements and be certified by third-party certification, such as CERTIFIRE or INTERTEK.

Certified Fire proof door Hardware:

Door hinge-BS EN1935

Door closer-BS EN1154

Door coordinator-BS EN1158

Mortise lock-BS EN12209

Panic exit device-BS EN1125

Emergency exit device-BS EN179


These are two international standards on fire doors that are authoritative. The right fire door hardware can save lives. Choosing certified products from reputable and reliable sources, ensuring correct installation and carrying out regular inspection and maintenance procedures will save lives.

 

The products that D&D offer are tested to the most stringent international industry standards, including BS EN, CE, UL, ANSI and BHMA, include fire rated door hinges, ANSI fire door hinges, Door handles, Mortise locks, Door closers, Panic exit devices and Door Accessories etc., suitable for Healthcare, Education, Hotel, Government, Apartment Building, Residential and Commercial applications.

 

D and D HARDWARE offers products that have been tested to the most stringent international industry standards, including BS EN, CE, UL, ANSI and BHMA, including fire door hinges, door handles, door locks, door closers, exit devices and door accessories for healthcare, education, hospitality, government, apartment buildings, residential and commercial applications.

 

For further information about Fire rated door hardware or door solution, click here.

Contact us Now:
Contact: David Jian
Mob:0086-139 2903 7292
Email: sales@danddhardware.com

Contanct Us

Get Famous Branded Quality at Factory Cost 12th Floor, Building 2, No.898, KeChuang Technical Zone,Jianghai Dist.Jiangmen City,Guangdong,China
   +86 139 2903 7292
   +86 139 2903 7292
  +86 139 2903 7292
 David Jian(Managing Director)
 Ms Judy(Financial / Account Dept. )

To get Famous Brand Quality at Low cost

 Copyright ©2021  D&D HARDWARE INDUSTRIAL Co., Ltd . All Rights Reserved. |Sitemap