English
한국어
Tiếng Việt
Deutsch
Português
Español
Pусский
Français
العربية
简体中文

Home » Door Hardware Resources » American Standard Door Hardware » UL Listed door hardware for fire-rated openings

Product Category

Door Hinge

UL Listed Fire Rated Hinge

ANSI / BHMA Door Hinge

CE Grade 13 Door Hinge

Spring Hinge

Security Door Hinge

Flag Hinge

Flush Hinge

Lift-off Door Hinge

Crank Hinge

Piano Hinge

Heavy Duty Door Hinge

Electrified Hinge

Brass Hinge

Hidden Hinge

CE EN1935 3D Hinge

Concealed Hinge

Adjustable Door Hinge

Panic Exit Device

CE Panic Exit Device

UL Fire Exit Hardware

UL305 Panic Hardware

Panic Door Bar

Exit Device Trim

Door Lock

CE EN12209 Mortise Lock

Euro Mortise Lock

UL Mortice Lock

ANSI Cylindrical Lockset

Door Knob Lock

Sliding Door Lock

Narrow Stile Lock

Padlock

Rim Lock

Smart Lock

Smart Door Locks

Hotel Door Lock

Door Closer

UL Listed Fire Door Closer

CE EN1154 Door Closer

Automatic Door Closer

Sliding Door Closer

Hydraulic Door Closer

Spring Door Closer

Commercial Door Closer

Door Coordinator

Lock Cylinder

BS EN1303 Lock Cylinder

Euro Lock Cylinder

Rim Cylinder

Key Cylinder

Cylinder Thumbturn

Door Handle

ANSI Door Handle

BS EN1906 Door Handle

Hollow Lever Handle

Solid Lever Handle

Narrow Frame Lever Handle

Backplate Door Handle

Rosette / Escutcheon

Door Stopper

Door Holder

Floor Door Stop

Wall Door Stop

Rubber Door Stop

Magnetic Door Stop

Half Moon Door Stop

Foot Operated Door Stop

Door Bolt

Flush Bolt

Barrel Bolt

Automatic Flush Bolt

Brass Door Bolt

Stainless Steel Door Bolt

Dust Proof Socket

Door Viewer

Glass Hardware

Glass Door Handle

Glass Door Hinge

Glass Clip

Patch Fitting

Floor Spring

Door Accessories

Ball Catch

Door Guard Chain

Sign Plate

Door Plate

Metal Door Fitting

Thumbturn Indicator

Door Seal

Door Bottom Seal

Intumescent Pads

Door Frame Seal

UL Listed door hardware for fire-rated openings

Publish Time: 2022-04-06     Origin: D and D Hardware


Fire-rated openings are used to compartmentalize a building or space to prevent the spread of flame, smoke and toxic gases. The 2019 edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives, establishes the criteria that fire-rated doors and frames must meet.

NFPA 80 requires side hinged and pivoted fire-rated doors and frames to be tested in accordance with established testing methods and procedures listed in NFPA 252, Standard Methods of Fire Test of Door Assemblies.


General Requirements for fire-rated openings

Chapter 4 of NFPA 80 covers the general requirements for all types of fire-rated assemblies. It defines the requirements for hardware preparations, glazing limitations, classifications of hardware for fire doors, and sills.


Fire-rated door assemblies consist of a:

Fire-rated frame

Fire-rated door

Labeled/Listed hanging device

Labeled latching device

Listed door closing device


Remark: Mechanical hold-open devices are not permitted to be used on fire-rated openings.


Labeled latching device:

Fire exit hardware consists of exit devices that have been tested and labeled for use on fire-rated openings. A label is attached to fire exit hardware in compliance with NFPA 80. Unlike panic hardware, fire exit hardware is not permitted to be mechanically dogged open.

Fire-rated doors that are required to have an exit device will have labels that state “Fire Door to Be Equipped with Fire Exit Hardware.” Only exit devices that have been tested and labeled for use on fire-rated assemblies can be used. Typically, doors with this label have been internally reinforced to receive the fasteners that attach fire exit hardware to the doors.


Listed door closing device:

Fire-rated doors must be able to swing easily in order for door closers to efficiently close the doors. NFPA 80 separates the closing operation of doors into three categories:

1, Self-Closing

Door closers on self-closing fire-rated doors return the door to the closed position and cause the latch to engage the strike after each opening cycle of the door. The door closers are not permitted to have a hold-open mechanism.

2, Automatic -Closing

Automatic-closing fire-rated doors are held open, either by an electrified door closer or by hold-open devices such as wall magnets that automatically release immediately upon actuation of the fire alarm system or power failure. When power is removed, the door-holding device releases, allowing the closer to close the door.

3, Power Operated Fire Doors

Power-operated fired doors are doors that are normally opened and closed by operators. In the case of fire or a power failure. The operators must release and allow the doors to function manually.


Labeled/Listed hanging device:

Labeled conventional hinges installed on fire-rated doors must be made from steel(ferrous) or stainless-steel metals. Ball bearing or antifriction bearing hinges are required to be used to ensure that the doors swing easily. Labeled pivots and continuous hinges also have bearings that permits the doors to operate easily.

NFPA 80 requires fire-rated openings to have two conventional hinges on openings up to 60 inches in height. One additional hinge is required for each additional 30 inches of door height or fraction thereof.

Where spring hinges are used, at least two shall be provided, they are not required to be ball bearing, but shall be labeled.



Labeled latching device:

Latching devices on fire-rated doors must be labeled for use on fire-rated assemblies. Latch bolts are not permitted to be mechanically held in the retracted position.

Locks with interconnected deadbolts that retract when the latch bolt is retracted shall be permitted for use on fire doors in a means of egress.

The throw of single point latch bolts shall not be less than the minimum shown on the label of the fire doors.


Labeled manually operated flush and surface bolts are permitted to be used on the inactive leaf of a pair doors where acceptable by the AHJ. This provision limits their use to rooms not normally occupied such as transformer vaults and storage rooms.

Pairs of fire doors that are needed for the movement of equipment where the inactive leaf is not required for egress purposes, are required to have labeled automatic or self-latching flush bolts or labeled two-point latches.


For further information about fire door hardware or any of our services, please click here.


Contact us Now:

Contact: David Jian

Mob: 0086-139 2903 7292

Email: sales@danddhardware.com



Contanct Us

Get Famous Branded Quality at Factory Cost 12th Floor, Building 2, No.898, KeChuang Technical Zone,Jianghai Dist.Jiangmen City,Guangdong,China
   +86 139 2903 7292
   +86 139 2903 7292
  +86 139 2903 7292
 David Jian(Managing Director)
 Ms Judy(Financial / Account Dept. )

To get Famous Brand Quality at Low cost

 Copyright ©2021  D&D HARDWARE INDUSTRIAL Co., Ltd . All Rights Reserved. |Sitemap