English
한국어
Tiếng Việt
Deutsch
Português
Español
Pусский
Français
العربية
简体中文

Home » Door Hardware Resources » Door Hardware Installation » How To Adjust a Door Closer: A Comprehensive Guide

Product Category

Door Hinge

UL Listed Fire Rated Hinge

ANSI / BHMA Door Hinge

CE Grade 13 Door Hinge

Spring Hinge

Security Door Hinge

Flag Hinge

Flush Hinge

Lift-off Door Hinge

Crank Hinge

Piano Hinge

Heavy Duty Door Hinge

Electrified Hinge

Brass Hinge

Hidden Hinge

CE EN1935 3D Hinge

Concealed Hinge

Adjustable Door Hinge

Panic Exit Device

CE Panic Exit Device

UL Fire Exit Hardware

UL305 Panic Hardware

Panic Door Bar

Exit Device Trim

Door Lock

CE EN12209 Mortise Lock

Euro Mortise Lock

UL Mortice Lock

ANSI Cylindrical Lockset

Door Knob Lock

Sliding Door Lock

Narrow Stile Lock

Padlock

Rim Lock

Smart Lock

Smart Door Locks

Hotel Door Lock

Door Closer

UL Listed Fire Door Closer

CE EN1154 Door Closer

Automatic Door Closer

Sliding Door Closer

Hydraulic Door Closer

Spring Door Closer

Commercial Door Closer

Door Coordinator

Lock Cylinder

BS EN1303 Lock Cylinder

Euro Lock Cylinder

Rim Cylinder

Key Cylinder

Cylinder Thumbturn

Door Handle

ANSI Door Handle

BS EN1906 Door Handle

Hollow Lever Handle

Solid Lever Handle

Narrow Frame Lever Handle

Backplate Door Handle

Rosette / Escutcheon

Door Stopper

Door Holder

Floor Door Stop

Wall Door Stop

Rubber Door Stop

Magnetic Door Stop

Half Moon Door Stop

Foot Operated Door Stop

Door Bolt

Flush Bolt

Barrel Bolt

Automatic Flush Bolt

Brass Door Bolt

Stainless Steel Door Bolt

Dust Proof Socket

Door Viewer

Glass Hardware

Glass Door Handle

Glass Door Hinge

Glass Clip

Patch Fitting

Floor Spring

Door Accessories

Ball Catch

Door Guard Chain

Sign Plate

Door Plate

Metal Door Fitting

Thumbturn Indicator

Door Seal

Door Bottom Seal

Intumescent Pads

Door Frame Seal

How To Adjust a Door Closer: A Comprehensive Guide

Publish Time: 2025-09-05     Origin: Site

A door closer is an essential piece of hardware that ensures doors close safely, securely, and quietly. Over time, you might notice issues like a door slamming too fast, not latching properly, or being overly difficult to open. Fortunately, most modern door closers are equipped with adjustable valves that allow you to fine-tune their performance. This guide will take you through the entire adjustment process.



Section 1: Prioritize Safety and Conduct Preliminary Checks

Before you start adjusting any valves, it's vital to understand the context of the door.


Fire-Rated Doors

If the door is a fire-rated or emergency exit door, it is part of a life-safety system. Incorrect adjustments can violate fire codes and create a hazardous situation during an emergency. In commercial settings, adjusting fire door closers often requires re-certification by a qualified professional. Look for a label on the door or the closer indicating that it is fire-rated.


Check for Damage

Inspect the closer body, arm, and the door itself for any visible signs of damage, leaks, or corrosion. A faulty closer should be replaced rather than adjusted.


Identify Your Closer

Most closers have the manufacturer and model number printed on the body. Knowing this information can help you find a specific manual online if needed. The most common types are overhead concealed closers (installed in the door frame header) and surface-mounted closers (mounted on the door or frame).



Section 2: Understanding the Adjustment Valves

Most standard door closers have two or three adjustment valves, typically hexagonal (Allen key) holes that are labeled or color-coded. You will usually need a dedicated L-key (a small, L-shaped Allen key), which often comes with the closer. Using the wrong size key can strip the valves.

The three main valves control the following aspects:


Swing Speed (Main Speed)

This valve controls the speed of the door from the fully open position through most of its swing until it is about 15 degrees from closing. It is often the largest valve.


Latching Speed

This valve controls the speed of the door during the last few degrees of closing (typically the last 5 - 15 degrees). It ensures that the door engages the latch smoothly and quietly without slamming.


Backcheck

Not all closers have this feature. If present, it controls the resistance and speed when the door is opened forcefully or thrown open. It acts as a cushion to prevent the door from swinging too fast and hitting the wall or other obstacles.


Valve Direction: A Universal Rule

  • Turn the valve clockwise (to the right): This restricts fluid flow, slowing down the action and providing more resistance.

  • Turn the valve counterclockwise (to the left): This increases fluid flow, speeding up the action and providing less resistance.


Crucial Tip: Make adjustments in small increments, no more than a quarter-turn at a time. Then, open and close the door to test the effect. Making dramatic turns can render the door inoperable or cause internal damage to the closer.


Section 3: Step-by-Step Adjustment Procedure

Follow this logical sequence for the best results.


Step 1: Prepare the Door

Fully open the door and let it close on its own. Observe its current behavior and identify what you want to change. Is it closing too fast or too slow? Does it fail to latch properly?


Step 2: Adjust the Main Swing Speed

Problem: The overall swing of the door is too fast (it slams) or too slow (it doesn't close).
Solution: Locate the main speed valve. Make a small turn (1/8 to 1/4) clockwise to slow it down or counterclockwise to speed it up.
Test: Open the door and let it close. Repeat this process until the main swing feels controlled and natural.


Step 3: Adjust the Latching Speed

Problem: The door slams shut violently in the final moment or creeps so slowly that it doesn't have enough energy to engage the latch.
Solution: Locate the latching speed valve. If the door is slamming, turn the valve clockwise a small amount to slow the final swing. If it's failing to latch, turn it counterclockwise a small amount to give it a bit more power.
Test: After each adjustment, let the door close. The ideal setting is a firm, positive, and quiet engagement with the strike plate.


Step 4: Adjust the Backcheck (If Present)

Problem: The door swings open too easily and hits the wall or stops violently.
Solution: Locate the backcheck valve. Open the door forcefully. If it offers too little resistance, turn the valve clockwise to increase the cushioning effect. If the door is too hard to open wide, turn it counterclockwise.
Test: Force the door open quickly after each adjustment until it feels properly cushioned.


Step 5: Check the Overall Operation

Once you are satisfied with each individual setting, operate the door several times at different speeds. Push it gently, let it go from a halfway point, and open it fully and forcefully. Ensure that it behaves correctly in all scenarios.


Section 4: Advanced Adjustments (Hydraulic Arm Action)

Some closers have a second arm connected to the main body via a slide mechanism. This controls the delayed action or sweep.


Delayed Action

This feature allows the door to stay open for a few seconds after being opened to a certain point before beginning to close. It's useful in high-traffic areas. It's usually adjusted by a valve on the slide mechanism itself, following the same clockwise/counterclockwise rule.


Hold-Open

Some closers are designed to hold the door open at a certain point (e.g., 90 or 110 degrees). To close it, you must pull it past the hold-open point. This is not typically adjustable and is a built-in function of the arm type.



Section 5: Troubleshooting Common Problems


Door Won't Close / Closer is "Weak"

The closer may be under-powered for the door's size and weight. Check the model number to ensure it's the correct grade (e.g., Grade 1 for heavy doors, Grade 3 for lighter ones). It could also indicate a loss of hydraulic fluid due to a leak, in which case the closer needs to be replaced.


Door Closes Too Fast No Matter the Adjustment

The internal seals may be worn out, or the wrong size closer may be installed.


Door Closes in Jerks or is "Choppy"

This almost always indicates that air has entered the hydraulic system, often due to a leak or the closer being installed upside down. The unit likely needs to be replaced.


Oil Leak

If you see fluid around the valves or body, the internal seals have failed. The closer must be replaced immediately.


Final Warning and Recommendation

If you are ever unsure, especially when dealing with critical fire-rated doors, stop and call a professional door hardware consultant or locksmith. Proper door operation is not just a matter of convenience; it is a fundamental component of building safety, security, and accessibility. For non-critical interior doors, careful and minimal adjustments can easily restore perfect, quiet operation for years to come.



D&D Door Closer Certification


CE Door Closer - EN1154 500,000 cycles test, EN1634 fire rated 120mins/180mins, EN1670 corrosion resistance 96 hours.


   


UL Door Closer - UL Listed, UL 10C fire rated 3 hours, UL File NO.R40717

      



For further information about door clsoer or any of our services, please click here.



Contact us Now:

Contact: David Jian

Mob: 0086-139 2903 7292

Email: sales@danddhardware.com


Adjustable Door Closer


Adjusting Door Closer



Contanct Us

Get Famous Branded Quality at Factory Cost 12th Floor, Building 2, No.898, KeChuang Technical Zone,Jianghai Dist.Jiangmen City,Guangdong,China
   +86 139 2903 7292
   +86 139 2903 7292
  +86 139 2903 7292
 David Jian(Managing Director)
 Ms Judy(Financial / Account Dept. )

To get Famous Brand Quality at Low cost

 Copyright ©2021  D&D HARDWARE INDUSTRIAL Co., Ltd . All Rights Reserved. |Sitemap