What Are The Types Of Fire Rated Door Hardware?

D&D's fire rated door hardware is ANSI/UL/CE approved and is available in a wide range of types and styles, such as hinges, locks,exit devices,door closers and door accessories.

Fire Rated Panic Exit Device

D and D Fire Rated Panic Exit Devices have passed ANSI A.156.3 Grade 1 (500,000 cycles test)and UL Listed 10C Fire Rated 3 Hours test. The exit-devices are available in stainless steel 304 and painted steel. Suitable for wooden doors, metal doors and fire-rated doors.

 
 

Fire Rated Door Closer

D and D Fire Rated Door Closers have been successfully types to all requirements of BS EN1154 60-120min ,UL Listed 10C 3 Hours Fire Rated.The Door Closers are made of Aluminum alloy ,available in a variety of styles and finishes.

 
 

Fire Rated Door Hinge

D and D Fire Rated Door Hinges have been successfully types to all requirements of BS EN1935,BHMA/ANSI A.156.1,UL 10C ,Fire Rated 3 Hours.The fire rated door hinges are made of Stainless Steel 304/201/316 and have different finishes.such as SSS,PSS,PVD,AB,AC,MB.

 
 

Fire Rated Door Lock

D and D Fire Rated Door Locks have been successfully types to all requirements of BS EN12209 / EN1634 260 min Fire Rated, EN1670 240 hours corrosion resistance.Solid SUS304 Latchbolt, Deadbolt, Follower, SUS304 Forend,Strike plate.

 
 

Fire Rated Mortice Lock

D and D Fire Rated American Standard Mortice Locks have been passed UL Listed 10C Fire Rated and BHMA/ANSI A.156.13-2005 Grade 1 test.The main of fire rated mortice lock is stainless steel 304. Suitable for wooden doors, metal doors and fire-rated doors.

 
 

Fire Rated Tubular Lockset

D and D Fire Rated Tubular Lockset certified to BHMA/ANSI A.156.2 Grade 1,Grade 2 and UL Listed Fire Rated. It is made of stainless steel and zinc alloy.The tubular lockset has functions for bedrooms, storage rooms, entrances,offices etc..

 
 
UL ANSL Panic Exit Device
CE UL Door Closer
ANSI UL CE Fire Rated Door Hinge
CE EN 12209 Mortise Lock

Main Markets

South Asia
Middle East
Western Europe
Nordic
North America
South America

D&D Fire Rated Door Hardware Certification

D&D's fire rated door hardware is ANSI/UL/CE approved and is available in a wide range of types and styles, such as hinges, locks,exit devices,door closers and door accessories.

Production - Code Compliance

ANSI/BHMA

ANSI/BHMA

- ANSI/BHMA A156.1: 2016 American National Standard for Butts and Hinges

- ANSI/BHMA A156.2 – 2003 Bored and Preassembled Locks and Latches

- ANSI/BHMA A156.3 Grade 1 Exit Devices

- ANSI/BHMA A156.13-2012 Mortise Locks & Latches

ANSI/UL

For SINGLE-POINT LOCKS AND LATCHES –Cylindrical Type:

ANSI/UL 10B, Fire Tests of Door Assemblies up to and including 3 hours

ANSI/UL 10C, Positive Pressure Fire Tests of Door Assemblies

UBC 7 2(1997); CAN4-S104-M80

 

For MORTISE LOCK

UL 10C, Standard for Safety for Positive Pressure Fire Tests of Door Assemblies, fire rated up to and including 1-1/2 hours

 

For FIRE-EXIT HARDWARE

ANSI/UL 305

NFPA80 National Fire Protection – Fire Door Assembly

NFPA101 National Fire Protection – Life Safety

ANSI/UL

For BUTTS AND HINGES

UL 10C, Positive Pressure Fire Tests of Door Assemblies

CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies

 

For SWING FIRE DOOR CLOSERS

UL 228, Door Closers-Holders, With or Without Integral Smoke Detectors

CAN/ULC-S133-07, Door Closers Intended for Use with Swinging Doors

UL 10C, Standard for Safety for Positive Pressure Fire Tests of Door Assemblies

EN

EN

- EN1935:2002/AC: 2003 Building hardware - Single-axis hinges

- EN1906:2012 Building hardware - Lever Handles and Knob Furniture

- EN12209:2003/AC: 2005 Building hardware - Locks and Latches

- EN1303:2015 building hardware- Cylinders for Locks

- EN1154:1996/ A1: 2002/ AC: 2006 Controlled Door Closing Devices

- EN1125:2008 & EN 179:2008 Panic and emergency exit devices

- EN1670:2007 Corrosion Resistance

- EN1634-1:2008 Fire Resistance Tests for Doors, Shutters and Operable Windows

- EN 1634-1:2014 Fire resistance Tests for Single-axis Hinges & Locks and Latches

Basic Fire Door requirement Check List

Fire doors are generally located in the following locations: closed evacuation stairs leading to walkways; closed elevator doors leading to the front and front rooms leading to the walkway doors. Inspection doors for vertical pipeline wells such as cable wells, pipeline wells, exhaust ducts, and garbage lanes. Divide the fire zone; control the firewall and fire door on the partition building area.
 What Is The Standard For Fire Door Position?
We have an excellent technical team, which can be designed according to customers requirements.
Basic-Fire-Door-requirement-Check-List
  • 01


     A fire door must have a label attached

     A fire door frame must have either an attached or an embossed label

  • 02

    A fire door must be self-latching.

     A fire door must be self-closinq.

  • 03

    If a fire door is held open, it must be equipped with the listed heat responsive device, fuse device or a smoke detection device.

     A fire door must be free of any obstructions which could prevent the door from operating properly, such as wedge door stops, chains. hook backs and so on.

Fire-proof doors shall be installed and maintained in accordance with NFPA standards.

The NFPA 80 regulations help ensure proper installation, inspection, testing and maintenance of fire door assemblies, fire window assemblies, fire dampers, fabric fire safety curtains and fire protection curtain assemblies. When it comes to change, everyone needs to know – from the manufacturer to the designer, engineer, contractor, AHJ, fire door inspector and building owner.

Therefore, fire door fittings also need to be installed and maintained in strict accordance with NFPA requirements.
Basic Fire Door requirement Check List:
 A fire door must have a label attached.
 A fire door frame must have either an attached or an embossed label.
 A fire door must be self-latching.
 A fire door must be self-closing.
 If a fire door is held open, it must be equipped with a listed heat responsive device, fusible link or a smoke detection device.
 A fire door must be free of any obstructions which could prevent the door from operating properly, i.e., wedge door stops, chains, hook backs, etc.
 Only listed fire door hardware shall be used.
 A fire door must have steel bearing-type hinges. (Exception: Non-bearing plain steel hinges may be used if they are part of a listed assembly.)
 Doors swinging in pairs that require astragals shall have at least one overlapping astragal. Pairs of doors within a means of egress shall not be equipped with an astragal that inhibits the free use of either leaf. A coordinator or open back strike should be used to ensure proper closing.
 Fire doors with glass lights: a. the glass frame and glazing bead must be metal. b. The glass must be labeled wire glass not less than 1/4" thick or as permitted by the labeling agency.
Fire doors with fusible link louvers: a. only listed louvers can be used. b. Louvers can be furnished in 1-3/4" thick doors with a 1-1/2-hour or a 3/4-hour (no louver and glass light combinations are permitted). c. Maximum louver size is 24" x 24". d. Louvers are not permitted to be installed in doors with fire exit hardware or in stairwells.

D&D Fire Rated Door Hardware Advantages
1
CE/UL/ANSI Certificated Hardware

Products tested to BS EN,CE, UL,ANSl and BHMA , adapt to market conditions, 5 Year Mechanical Guarantee.

2
Global Expertise Knowledge

Qualified experienced team who can help our customers find the right solution most suitable for their Needs,dedicated to a mutually-rewarding, long-term relationship.




​​​​​​​

3
Direct Supply Chain, Manufacturer

We have ongoing relationships with multiple manufacturing sources.  This means we are more able to maintain a reliable supply chain for us and for you.

4
Door Solution Design


Own Design team, custom made solutions always possible, we always strive to add value and adapt to client market.

Fire Rated Door Hardware Solutions

D&D Hardware offers not only fire rated door hardware, but also solutions for fire rated door hardware
  • [Stairwell Emergency Exit Door] Fire Rated Double Metal Door Solution for Staircase Escape Door-American Configuration
    Fire Exit Hardware is an exit device which is tested for both panic and fire conditions and is required to be used on fire doors where panic hardware is required by code or desired for durability. D&D Hardware escape gallery door hardware solution does just that for you. As an complete solution, yo Read More
  • [Escape Gallery Single Door] Fire Rated Single Metal Door Solution for Escape Route -American Configuration
    Escape Route - Swing Type Single Metal Door With Overlap- Fire Rated – American StandardSecurity, safety,function and convenience are the foundation of door hardware that architects, builders, and designers, and end users expect from D and D Hardware. D&D door hardware is manufactured to meet the n Read More
  • [Escape Gallery Single Door] Fire Rated Single Wood Door Solution for Esacpe Route-Amercian Configuration
    In the world, there are more and more topics of safety. For example,environmental safety,hardware safety and so on. For the Hardware Safety, D&D Hardware can provide complete hardware solutions for office single door. As an complete solution, you can view the top-rated door hardware combination for Read More

Fire Rated Door Hardware Project

D&D fire rated door hinge comply to ANSI,BHMA,UL and BS EN/CE, Suitable for Residential Building, Office Building,Education, Healthcare, Hotel, Government applications.We can supply international branded quality at factory cost with mechanical guarantee and after sales service.
Government
Education  
Office Building
Healthcare
Commercial
Hotel

The Exhibition Hall

Contact us For Increase Your Profits and Market Shares.

D & D Hardware has established long business relations with customers from America, Europe, Middle East and Asia, Selling our items are proved to be profitable,collection approve by consultants,international branded quality with certifications from Intertek/UL.

Tel/WhatsApp/WeChat

+86 139 2903 7292

Address

12th Floor , Building 2, No. 898, KeChuang Technical Zone, Jiangmen Avenue, Pengjiang District, Jiangmen City, Guangdong, China

Contact us For Increase Your Profits and Market Shares
We'd Like To Assist You Find 
The Right Solution For Your Needs.

Contanct Us

  NO.4 Bidg,Street 33,West Gaoxin Rd,High-tech Zone,Jianghai Dist.Jiangmen City,Guangdong,China
   +86 139 2903 7292
   +86 139 2903 7292
  +86 139 2903 7292
 David Jian(Managing Director)
 Ms Judy(Financial / Account Dept. )

Navigation

To get international branded quality at factory cost
 Copyright ©2021  D&D HARDWARE INDUSTRIAL Co., Ltd . All Rights Reserved. |Sitemap
We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×